[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
Indexing & Abstracting::
Publication Ethics::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Indexing & Abstracting
DOAJ
GOOGLE SCHOLAR
..
:: Volume 9, Issue 2 (7-2004) ::
__Armaghane Danesh__ 2004, 9(2): 31-39 Back to browse issues page
Comparison of Systolic Blood Pressure Measurement by Pulse Oximetery and Auscultatory Method
N Farhadi 1, A Khosravi , KA Zandi Ghashghaie
1- , rahfar196@yhoo.com
Abstract:   (3787 Views)
ABSTRACT Introduction & Objective: There are many noninvasive methods to measure systolic blood pressure. A new noninvasive method by pulse oximetery has recently been reported. The purpose of this study was the comparison of systolic blood pressure measurement by pulse oximetery and with auscultatory method. Material & Methods: Systolic blood pressure measurement using pulse oximeter was compared with current auscultatory method. Thirty one healthy volunteers enrolled and were positioned in supine, prone and lithotomy for three 10 minutes periods. Blood pressure was measured at the end of each position by two methods. Results: There was a significant correlation between two method in all positions supine (r= 0.72), prone (r= 0.88) and lithotomy (r= 0.78). Conclusion: Pulse oximeter seems to be a useful non-invasive method of systolic blood pressure measurement. In order to increase the accuracy of this method, low speed of cuff inflation and deflation is strongly recommended.
Keywords: KEY WORDS: Systolic blood pressure Measurement, Pulse oximeter, Positions
Full-Text [PDF 178 kb]   (1078 Downloads)    
Type of Study: Research | Subject: Special
Received: 2015/06/10 | Accepted: 2015/06/10 | Published: 2015/06/10
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Farhadi N, Khosravi A, Zandi Ghashghaie K. Comparison of Systolic Blood Pressure Measurement by Pulse Oximetery and Auscultatory Method. armaghanj 2004; 9 (2) :31-39
URL: http://armaghanj.yums.ac.ir/article-1-825-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 9, Issue 2 (7-2004) Back to browse issues page
ارمغان دانش Armaghane Danesh
Persian site map - English site map - Created in 0.05 seconds with 39 queries by YEKTAWEB 4645