[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
Indexing & Abstracting::
Publication Ethics::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Indexing & Abstracting
DOAJ
GOOGLE SCHOLAR
..
:: Volume 12, Issue 2 (7-2007) ::
__Armaghane Danesh__ 2007, 12(2): 1-9 Back to browse issues page
The Effect of Low Flow Inhalation Anesthesia on Operative Hemodynamic Condition in Comparison with High Flow Anesthesia
M Eidi , H Hoseinzade , KH Kolahdozan 1, D Aghamohammadi
1- , Khosro_kolahdozan@yahoo.com
Abstract:   (6001 Views)
Introduction & Objective: Low flow anesthesia technique in which the flow fresh gas is lower than minute volume of the patient results in improvement in the patient’s care such as reduction of operative hypothermia, reduction of postoperative shivering and leads to an increase in economical and enviornmental interests. The goal of the study was to investigate the patients’ operative hemodynamic variations using the high and low flow anesthesia techniques. Materials & Methods: This prospective, clincal and single blind study was carried out in Tbriz Emam Khomeini Hospital in 1384. In this study 97 patients in ASA class I or II after routine induction of G.A, during maintenance of anesthesia were randomly divided in two groups group I (high flow anesthesia) and group II (low flow anesthesia). For all patients ECG, HR, SPO2, BP, B.T, ETCO2 and inspiratory, expiratory percentage of O2, N2O, halothane, postoprative shievring and duration of oprations were recorded. 46 patients underwent high flow anesthesia and 51 patients underwent low flow anesthesia. Results: The average blood pressure in group I was as follow: preoperative, systol=13820 mmHg and diastol=7815 mmHg, intraoperative, systol=10531 mmHg and diastol=6410 mmHg and in recovery systol=11615 mmHg and diastol=7013 mmHg. In group II who had low flow anesthesia the blood pressure was found to be systol=13922 mmHg and diastol=7922 mmHg preoperative, systol=12221 mmHg and diastol=7517 mmHg intraoperative and systol=11815 mmHg and diastol=7717 mmHg in recovery. The differences in blood pressure in both group were statiscally significant (p=0.01). The average heart rate in group I was 9018 beat/min preoperative, 7014 intraoperative and 126 in recovery. The avrage heart rate in group II was 87.921 preoperative, 8616 intraoperative and 10417 in recovery. The differences were statiscally significant but there was no significant difference between the two groups with regard to sex, age and weight. Conclusion: Maintenance of anesthesia with low flow anesthesia gasses maintains more hemodynamic condition during operation.
Keywords: Low Flow Anesthesia, High Flow Anesthesia, Hemodynamic
Full-Text [PDF 122 kb]   (1659 Downloads)    
Type of Study: Research | Subject: Special
Received: 2015/06/2 | Accepted: 2015/06/2 | Published: 2015/06/2
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Eidi M, Hoseinzade H, Kolahdozan K, Aghamohammadi D. The Effect of Low Flow Inhalation Anesthesia on Operative Hemodynamic Condition in Comparison with High Flow Anesthesia . armaghanj 2007; 12 (2) :1-9
URL: http://armaghanj.yums.ac.ir/article-1-683-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 12, Issue 2 (7-2007) Back to browse issues page
ارمغان دانش Armaghane Danesh
Persian site map - English site map - Created in 0.04 seconds with 39 queries by YEKTAWEB 4645