[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
Indexing & Abstracting::
Publication Ethics::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Indexing & Abstracting
DOAJ
GOOGLE SCHOLAR
..
:: Volume 14, Issue 3 (10-2009) ::
__Armaghane Danesh__ 2009, 14(3): 113-120 Back to browse issues page
Dosimetric Calculations of a Radioactive Eye Plaque used in Management of Ocular Melanoma Using Monte Carlo Simulations
P Shokrani 1, Gh Raisali , A Janati
1- , shokrani14@yahoo.com
Abstract:   (4219 Views)
Introduction & Objective: Brachytherapy using I-125 radioactive seeds in removable episcleral plaques (EP) is often used in treatment of ocular malignant melanoma. Some radioactive seeds are fixed in a gold bowl-shaped plaque. The plaque is sutured to the sclera surface corresponding to the base of the intraocular tumor, allowing for a localized radiation dose delivery to the tumor. Minimum target doses as high as 85Gy are directed at malignant tumor. The aim of this study was to develop a Monte Carlo simulation of an ocular plaque in order to calculate the resulting isodose distributions. Materials & Methods: The MCNP-4C Monte Carlo code is used to simulate the plan of an episcleral plaque treatment. A 20-mm Collaborative Ocular Melanoma Study (COMS) plaque with 3, I-125 seed of model 6711 was used. Resulting dose distributions, including central axis dose and off-axis dose profiles, were calculated in a water phantom with 12mm radius. The calculated dose distributions were compared to the corresponding dose measured by Knuten et al., 2001. Results: Central axis dose calculations represent a rapid dose fall off, which is an important factor in selection of appropriate eye plaque for management of tumors with known dimension. Calculated off-axis dose profiles show decreased dose uniformity at distances close to the plaque. Increasing of distance from the plaque resulted in increasing of the dose uniformity. Conclusion: Monte Carlo simulation of eye plaques can be used as a useful tool in process of design, development and treatment planning of ocular radioactive plaques.
Keywords: Brachytherapy, Dosimetric Calculation, Monte Carlo
Full-Text [PDF 131 kb]   (996 Downloads)    
Type of Study: Research | Subject: Special
Received: 2015/05/30 | Accepted: 2015/05/30 | Published: 2015/05/30
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Shokrani P, Raisali G, Janati A. Dosimetric Calculations of a Radioactive Eye Plaque used in Management of Ocular Melanoma Using Monte Carlo Simulations. armaghanj 2009; 14 (3) :113-120
URL: http://armaghanj.yums.ac.ir/article-1-619-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 14, Issue 3 (10-2009) Back to browse issues page
ارمغان دانش Armaghane Danesh
Persian site map - English site map - Created in 0.05 seconds with 39 queries by YEKTAWEB 4645